Aseptic filling - benchtop fillers

620 series dispensing pumps

Overview

620Di dispensing pumps

Features and benefits

  • Keypad entry of flow from 0.001 L/min to 18 L/min
  • Dispenses 500 ml to within +/- 0.5 %
  • Stores up to 50 dispensing programs
  • Up to 4 bar pressure
  • 2650:1 control ratio (0.1 to 265 rpm speed range)
  • Digital speed adjustment with choice of 0.1 rpm, 0.5 rpm, 1 rpm, 2 rpm, 5 rpm and 10 rpm step changes
  • Maintenance-free brushless DC motor
  • Smooth easy-to-clean enclosure free from bug traps

Technical summary

Filling volume range Up to 500ml in 2.4s, Up to 500ml in 3.0s ml
Accuracy±0.5 %

Technical Summary table lists features available within the range. See ‘Technical specifications’ tab for model specific information.

Performance

Performance - 620L and 620LG pumpheads

Flow ranges (L/min) Y element tubing Continuous tubing
(over 0.1 to 265rpm speed range) (single channel) (flow per channel - max of 2 channels)
Tubing material 8.0mm 12.0mm 16.0mm 8.0mm 12.0mm 16.0mm
Pumpsil silicone 0.002-4.6 0.003-8.5 0.005-11.5 0.001-2.3 0.002-4.3 0.003-5.8
Marprene, Bioprene 0.002-4.6 0.003-8.5 0.005-11.5 0.001-2.3 0.002-4.3 0.003-5.8
Neoprene 0.002-4.6 0.003-8.5 0.005-12.6 0.001-2.3 0.002-4.3 0.003-6.3
STA-PURE PCS (620LG pumphead only) 0.002-5.2 0.003-9.0 0.005-12.4 0.001-2.6 0.002-4.5 0.003-6.2
620L dose sizes
Tube bore 8.0mm 12.0mm 16.0mm
Minimum possible dose 8ml 16ml 22ml
Minimum recommended 84ml 161ml 218ml
620LG dose sizes (STA-PURE PCS®, STA-PURE PFL®)
Tube bore 8.0mm 12.0mm 16.0mm
Minimum possible dose 10ml 17ml 23ml
Minimum recommended 99ml 167ml 234ml

Performance - 620R, 620RE, 620REH pumpheads

Flow ranges (L/min) Continuous tubing LoadSure™ element tubing
(over 0.1 to 265rpm speed range) 620R (2 rollers) 620RE (2 rollers) 620RE (2 rollers)
Tubing material 6.4mm 9.6mm 12.7mm 15.9mm 12mm 17mm 12mm 17mm
Marprene TM, Bioprene TM 0.004-9.8 0.01-16 0.003-8.3 0.004-11
Marprene TL, Bioprene TL 0.001-3.4 0.003-6.6 0.004-11 0.01-12 0.004-9.8 0.01-18 0.003-8.3 0.005-12
Pumpsil silicone 0.001-3.2 0.003-7.2 0.004-11 0.01-15 0.004-10 0.01-16 0.003-8.7 0.004-11
STA-PURE, Neoprene 0.001-3.2 0.003-6.6 0.004-11 0.01-16 0.004-11 0.01-18 0.003-9.0 0.010-13
620L dose sizes
Tube bore 6.4mm (1/4”) 9.6mm (3/8”) 12.7mm (1/2”) 15.9mm (5/8”)
Minimum possible dose 6ml 14ml 21ml 28ml
Minimum recommended 60ml 136ml 208ml 283ml
620RE dose sizes
Tube bore 12mm 17mm
Minimum possible dose 19ml 30ml
Minimum recommended 189ml 302ml
620RE4 dose sizes
Tube bore 12mm 17mm
Minimum possible dose 16ml 21ml
Minimum recommended 164ml 208ml

Specifications

Technical specifications

620L pumphead620LG pumphead620R pumphead620RE pumphead620REH pumphead
Filling volume range Up to 500ml in 2.4s mlUp to 500ml in 2.4s mlUp to 500ml in 3.0s mlUp to 500ml in 3.0s mlUp to 500ml in 3.0s ml
Accuracy±0.5 %±0.5 %±0.5 %±0.5 %±0.5 %
Ingress ratingIP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X 
Operating temperature range5 - 40 °C5 - 40 °C5 - 40 °C5 - 40 °C5 - 40 °C
Operating temperature range40 - 104 °F40 - 104 °F40 - 104 °F40 - 104 °F40 - 104 °F
Speed control ratio2650:1 2650:1 2650:1 2650:1 2650:1 
Humidity(Condensing) 10-100% RH, (Non-condensing) 80% up to 31°C (88°F), decreasing linearly to 50% at 40C (104F) (Condensing) 10-100% RH, (Non-condensing) 80% up to 31°C (88°F), decreasing linearly to 50% at 40C (104F) (Condensing) 10-100% RH, (Non-condensing) 80% up to 31°C (88°F), decreasing linearly to 50% at 40C (104F) (Condensing) 10-100% RH, (Non-condensing) 80% up to 31°C (88°F), decreasing linearly to 50% at 40C (104F) (Condensing) 10-100% RH, (Non-condensing) 80% up to 31°C (88°F), decreasing linearly to 50% at 40C (104F) 
Noise<70dB(A) at 1m <70dB(A) at 1m <70dB(A) at 1m <70dB(A) at 1m <70dB(A) at 1m 
StandardsCE, cETLus CE, cETLus CE, cETLus CE, cETLus CE, cETLus 
Power supply100-120 V, 200-240 V, 50/60 Hz, Single-phase 100-120 V, 200-240 V, 50/60 Hz, Single-phase 100-120 V, 200-240 V, 50/60 Hz, Single-phase 100-120 V, 200-240 V, 50/60 Hz, Single-phase 100-120 V, 200-240 V, 50/60 Hz, Single-phase 
Weight24.3 - 25.2 kg24.3 - 25.2 kg19.6 - 20.5 kg19.6 - 20.5 kg20.1 - 21 kg
Weight53.6 - 55.6 lbs53.6 - 55.6 lbs43.2 - 45.2 lbs43.2 - 45.2 lbs44.3 - 46.3 lbs
AccessoriesFootswitch, handswitch, RS232 cable, batch records cable Footswitch, handswitch, RS232 cable, batch records cable Footswitch, handswitch, RS232 cable, batch records cable Footswitch, handswitch, RS232 cable, batch records cable Footswitch, handswitch, RS232 cable, batch records cable 
Compatible tubing size12.0 mm ID, 16.0 mm ID, 4.0 mm wall thickness, 8.0 mm ID 12.0 mm ID, 16.0 mm ID, 4.0 mm wall thickness, 8.0 mm ID 12.0 mm ID, 12.7 mm ID, 15.9 mm ID, 17.0 mm ID, 6.4 mm ID, 9.6 mm ID 12.0 mm ID, 12.7 mm ID, 15.9 mm ID, 17.0 mm ID, 6.4 mm ID, 9.6 mm ID 12.0 mm ID, 12.7 mm ID, 15.9 mm ID, 17.0 mm ID, 6.4 mm ID, 9.6 mm ID 

Dimensions - 620L and 620LG pumpheads

Dimensions - 620R, 620RE and 620RE4 pumpheads

Materials of construction

BearingsCarbon steel
CaseworkPressure die-cast aluminum LM24, Pressure die-cast aluminum LM6
Keypad/HMIPolyester
Pumphead roller assemblyNylatron, Stainless steel

Control

Control options

Functionality 620Di 620DiN
Enclosure - ingress protection rating IP31 IP66
Manual control
Digital speed control with simple calibration to display flow
Choice of flow rate display; metric or imperial units
Numeric keypad for entry of speed, flow or PIN code
Remote control
Run/stop, direction change, auto/manual mode, leak detector input (via contact closure or 5V TTL to 24V industrial logic)
Remote operation of dosing (foot/handswitch or logic input)
Four programmable digital status outputs through 5V TTL to 24V industrial logic
Analogue speed feedback
Tachometer output; 0-1478Hz
Digital communication
Digital network serial control RS232 RS485 RS232 RS485
Specialist dispensing functionality
Drip control feature (momentary direction reverse at end of dose)
Ramp control to improve accuracy and avoid splashing or frothing
Export of batch records to PC or printer for cGMP requirements RS232 RS232
Dual operator/supervisor PIN code protection of pump settings

Literature

Brochures

  1. Dispensing pumps (US).pdf
    PDF - 612.6kb

Datasheet

  1. 620Di and 620DiN pumps with 620R, 620RE and 620RE4 pumpheads datasheet.pdf
    PDF - 391.1kb
  2. 620Di and 520DiN pumps with 620L and 620LG pumpheads datasheet.pdf
    PDF - 212.1kb

Manuals

  1. 620 Di-DiN manual (EN).pdf
    PDF - 1.9mb

Order Information

Product codes

Ordering information - 620L and 620LG pumpheads

Product codes
620L pumphead 620LG pumphead Accessories
Pumphead only 063.4603.000 063.4623.000 Footswitch Handswitch RS232 cable Batch records cable
IP31/NEMA 2 wipe-down pumps IP31 IP31 IP31 IP31
620Di 060.4171.5L0* 060.4171.5G0* 059.3002.000 059.3022.000 059.3121.000 059.3125.000
* Replace 0 (plug-less) with A, E or U for 2.8m American, European or UK mains plug
IP66/NEMA 4X wash-down pumps IP55 IP65
620DiN 060.417N.5L0** 060.417N.5G0** 069.5231.000 n/a n/a 059.450N.520
** Replace 0 (plug-less) with A for 2.8m American mains lead
Y element tubing Continuous tubing
8.0mm 16.0mm 12.0mm Tubing material
Pumpsil silicone 913.AE80.K40 913.A12E.K40 913.A16E.040 913.A080.040 913.A120.040 913.A160.040
Marprene 902.E080.K40 902.E120.K40 902.E160.040 902.0080.040 902.A120.040 902.0160.040
Bioprene 933.E080.K40 933.E120.K40 933.E160.040 933.0080.040 933.A120.040 933.0160.040
Neoprene 920.E080.K40 920.E120.K40 920.E160.040 920.0080.040 920.A120.040 920.0160.040
STA-PURE PCS (for 620LG pumphead) 960.E080.K40 960.E120.K40 960.E160.040
STA-PURE PFL (for 620LG pumphead) 965.E080.K40 965.E120.K40 965.E160.040
Clamp set for continuous tube 069.4001.000
NB: 4 bar pressure capability with STA-PURE PCS elements (620LG pumphead only)

Ordering information - 620R, 620RE and 620REH pumpheads

Pump, Pumpheads and accessory codes
Pumpheads Accessories
620R MkII head 620RE MkII head 620RE4 MkII head Footswitch Handswitch RS232 cable Batch records cable
Pumphead only 063.4211.000 063.4231.000 063.4231.000
IP31/NEMA 2 wipe-down pumps IP31 IP31 IP31 IP31
620Di 060.4171.020* 060.4171.E20* 060.4171.E40* 059.3002.000 059.3022.000 059.3121.000 059.3125.000
*Replace 0 (plug-less) with A, E or U for 2.8m American, European or UK mains plug
IP66/NEMA 4X wash-down pumps IP55
620DiN 060.417N.020** 060.417N.E20** 060.4171.E40** 069.5231.000 n/a n/a
** Replace 0 (plug-less) with A for 2.8m American mains lead
Tubing
Continuous tubing for 620R Sanitary LoadSure™ elements (3/4” Tri-clamp PVDF connectors) Industrial LoadSure™ elements (3/4” Cam & Groove PP connectors)
6.4mm 9.6mm 12.7mm 15.9mm 12mm 17mm 12mm 17mm
STA-PURE 960.0064.032 960.0096.032 960.0127.032 960.0159.032 960.0120.PFT 960.0170.PFT
CHEM-SURE 965.0064.032 965.0096.032 965.0127.032 965.0159.032 965.0120.SST* 965.0170.SST*
Bioprene TM 903.P120.PFT 903.P170.PFT
Bioprene TL 903.0064.032 903.0096.032 903.0127.032 903.0159.032 903.0120.PFT 903.0170.PFT
Marprene TM 902.P120.PPC 902.P170.PPC
Marprene TL 902.0064.032 902.0096.032 902.0127.032 902.0159.032 902.0120.PPC 902.0170.PPC
Pumpsil silicone 913.A064.032 913.A096.032 913.A127.032 913.A159.032 913.A120.PFT 913.A170.PFT 913.A120.PPC 913.A170.PPC
Neoprene 920.0064.032 920.0096.032 920.0127.032 920.0159.032 920.0120.PPC 920.0170.PPC
PVC 950.0064.032 950.0096.032 950.0127.032 950.0159.032
NB: 4 bar pressure capability with Sta-Pure, Bioprene TM and Marprene TM *SST = sanitary stainless steel connectors

Recommended Products

  1. Accusil tubing

    Accusil tubing

    Tubing for accurate filling with excellent dispensing accuracy ± 0.5 %. Eight sizes available.

    Single-use assemblies

Related Products

  1. 520Di dispensing pumps

    520Di dispensing pumps

    Dispensing pump for flow rates to 3.5 L/min and pressures up to 4 bar.

    Aseptic filling - benchtop fillers

  2. PF22

    PF22

    Tabletop aseptic filling machine for <5 ml to >5000 ml. Accuracy of ±0.5 % on most volumes prevents costly overfilling.

    Aseptic filling - benchtop fillers

  3. PF7 table top filler

    PF7 table top filler

    Tabletop aseptic filling machine for <0.2 ml to >250 ml. Accuracy of ±0.5 % on most volumes prevents costly overfilling.

    Aseptic filling - benchtop fillers